Model 3009SA
3009SA Automatic Safety Analyzer is ideally suited for fast paced production lines delivering high volumes of finished household appliances.
This Automatic safety Analyzer has been widely appreciated by many household appliance manufacturers in India such as Tecumseh, Havells, Hitachi, IFB, LG, Voltas, Videocon, Yash fans to name a few.

APPLICATIONS
  • Table and Ceiling fans
  • Washing machines
  • Fridges
  • Air conditioners
  • Compressors


  • BENEFITS
  • User friendly front panel controls
  • User defined limits and test times
  • Auto/Manual test mode option for the operator
  • Remote Start/Stop switch to start the Test cycle
  • Fast, accurate and completes one test cycle in 10 sec
  • Audio/Visual alarm indication for the operator
  • Housed in dust free enclosure





  • TEST SPECIFICATIONS
    The Automatic Safety Analyzer performs the tests in the following sequence and in case of a fault; it stops the sequence of tests & sets off a buzzer alarm to the user.
    I) Ground Test
    The Ground Efficiency test checks the connection of the cable or ground wire that comes from the plug to the rack of the appliance by applying a 10 volts (A.C) to the circuit terminal and picking up the potential drop across it.
     Display  3½ Digits LED Display
     Test Voltage  10V
     Test Current  25A
     Test Time  0-10 sec
     Limit  0-10V
    II) I.R (Megohm) Test
    The IR test checks the strength of the ground wall insulation of the appliance that can be damaged due to dirt, carbon, moisture or weak wire insulation.
     Display  3½ Digits LED Display
     Test Voltage  500V (DC)
     Test Time  0-10 sec
     Limit  0-200 MΩ
    III) H.V Flash Test
    The H.V Flash test once again checks the strength of the ground wall insulation of the appliance but at a higher applied voltage than the I.R test. If there is sudden surge in the leakage current it indicates that the ground wall insulation is weak and the test has failed.
     Test Voltage  0-2.5KV AC
     Display  3½ Digits LED Display
     Test Time  0-10 sec
     OverTrip Leakage Current
     Leakage Current Limit  0.1-10mA
     Display  3½ Digits LED Display
    IV) Leakage Current Test
    The Leakage current test detects the current existing between the inside circuits with applied voltage and the external metallic parts of the appliance.
     Test Voltage 230 + 10%
     Display  3½ Digits LED Display
     Test Time  0-10 sec
     Leakage Current
     Leakage Current Limit  0.1-10mA
     Display  3½ Digits LED Display
    V) Low Voltage (Startability) Test
    The Low Voltage test checks the Input current drawn by the appliance at an input voltage specified by the user depending on the type of appliance. The user can also define the upper and lower limits of the input current and if the current is within the specified limits then test is successful else in case of a failure the test sequence is stopped and the audio/visual alarm is set off to notify the operator about the failure.
     Test Voltage  0-270 volts AC
     Display  3½ Digits LED Display
     Test Time  0-10 sec
     Input Current
     Upper Limit  0-20 amps
     Lower Limit  0-20 amps
     Display  3½ Digits LED Display
    VI) Full Voltage Run Test
    The Full voltage Run test also checks the Input current drawn by the appliance at an input voltage specified by the user depending on the type of appliance. The user can also define the upper and lower limits of the input current and if the current is within the specified limits then test is successful else in case of a failure the test sequence is stopped and the audio/visual alarm is set off to notify the operator about the failure.
     Test Voltage  0-270 volts AC
     Display  3½ Digits LED Display
     Test Time  0-10 sec
     Input Current
     Upper Limit  0-20 amps
     Lower Limit  0-20 amps
     Display  3½ Digits LED Display
    Optional Wattmeter has been provided to indicate the wattage of the appliance under test.